Send Message
Foshan Yingli Gensets Co., Ltd.
About us
Your Professional & Reliable Partner.
Foshan Yingli Gensets Co.,Ltd is located in Guanglong Area, Chencun Town, Shunde District,Foshan,Guangdong Province and just close to Guangzhou South Railway Station. The companyhas more than 20 years' experience producing generator and focusing on researching and newproduct developing. It is a high-tech company which combines developing, producing, selling,repairing and serving part in one. The product has been sold to more than 70 foreign countriesand also highly appreciated. Of course, all of ...
Learn More

0

Year Established

0

Million+
Employees

0

Million+
Customers Served

0

Million+
Annual Sales
China Foshan Yingli Gensets Co., Ltd. HIGH QUALITY
Trust Seal, Credit Check, RoSH and Supplier Capability Assessment. company has strictly quality control system and professional test lab.
China Foshan Yingli Gensets Co., Ltd. DEVELOPMENT
Internal professional design team and advanced machinery workshop. We can cooperate to develop the products you need.
China Foshan Yingli Gensets Co., Ltd. MANUFACTURING
Advanced automatic machines, strictly process control system. We can manufacture all the Electrical terminals beyond your demand.
China Foshan Yingli Gensets Co., Ltd. 100% SERVICE
Bulk and customized small packaging, FOB, CIF, DDU and DDP. Let us help you find the best solution for all your concerns.

quality Professional Silent Generator & Gas Generator Set manufacturer

Find Products That Better Meet Your Requirements.
Cases & News
The Latest Hot Spots
YC16VCG Natural gas generator group
High reliability   On the basis of the design and production platform of mature products, Yuchai has independently developed and manufactured high-temperature wear-resistant materials suitable for gas generator sets, as well as high-strength cylinder block, cylinder head, camshaft, crankshaft, common base and other major components, greatly improving the reliability and durability of products.       High efficiency and environmental protection   Using mature thin combustion, capacitive high energy ignition module, Yuchai patent combustion chamber, oxygen sensor closed-loop control and other technologies to ensure efficient and clean combustion of gas, accurate control of air-fuel ratio, Improve performance consistency and stability while ensuring low emissions.   Low maintenance cost   Using Yuchai patented cylinder liner, piston ring and valve sealing technology, Significantly reduce the oil consumption rate, The lubricating oil replacement cycle exceeds 1000h. The gas generator set is equipped with parts with good versatility and easy maintenance. Significantly reduce the maintenance cost of power generation equipment.     Safety protection   Independent and mature unit control system, Control system control stability, Set knock monitoring for each cylinder, Real-time monitoring of the whole machine status, Ensure machine safety.     Dynamo     The generator has the advantages of high power generation efficiency, low temperature rise, low waveform distortion rate, good dynamic performance, and stable parallel operation of AVR. With first-class reliability and durability, Can meet all kinds of harsh environment requirements.                    

2024

02/23

What is the composition and function of Cummins generator cooling system
Cummins diesel generators generate heat when they run, leading to an increase in body temperature. When the body temperature rises to a certain extent, it will affect the efficiency of Cummins generator. Therefore, measures are taken to keep the engine and AC Cummins generator at a low temperature. The cooling system includes a radiator, axial fan and thermostat. Ac Cummins generator with individual fan cooling.   What is the composition and function of Cummins generator cooling system   Radiator: Various dirt on the radiator chip will greatly reduce the cooling performance of the radiator, so it is necessary to clean the radiator frequently in a dusty environment.   Coolant: Engine coolant has three functions: to provide sufficient force transfer; Prevent corrosion of all metal materials in the cooling system; Provide adequate frost protection.   Select qualified brands of coolant to ensure the normal use of the engine. The coolant should be mixed with water, antifreeze or water and antirust liquid, where the PH value of water should be 6 to 8.   The coolant should be contained in the freezing area 40* ~ 60* It is recommended that the user use antifreeze 50* Cummins generator antifreeze and 50* pure water mixture should be prepared separately in an independent container, mixed evenly and added to the tank, and the antifreeze capacity can reach about -30 ℃. (See antifreeze user instructions for details).   Antirust fluid can be used in areas where there is no risk of freezing, rather than antifreeze. The mixing ratio of anti-rust liquid and pure water is 1:30, which can achieve better anti-rust cooling performance without reducing the Cummins generator. After the Cummins generator is filled with anti-rust liquid, it should be used to run to the heat engine state to obtain anti-corrosion protection.   Do not mix different types of antifreeze with additives such as rust prevention, as it will produce a large amount of foam and reduce its cooling performance.   Add coolant: Coolant can be added after the Cummins generator is shut down and completely cooled. The Cummins generator should not be started until the system is ventilated and coolant filled.When injecting coolant, the liquid level should reach 5 cm below the welded surface of the injection port (or the coolant level indication scale). After the coolant is filled, the Cummins generator should be started and preheated to check the coolant surface and determine whether the coolant needs to be replenished.   The coolant of the same specifications as the original cooling system should be the coolant. Before adding coolant to the cooling system, ensure that the drain cap is closed and the drain plug is located in the correct position.Add coolant slowly and evenly to avoid bubble faulting in the system. The air of the cooling system is discharged through the filling port or exhaust valve. If the cooling system is connected to the heater, the control valve of the heater is opened to maintain ventilation in the unit.The Cummins generator part is equipped with a coolant filter, and the filter valve is opened before being officially put into use.

2024

01/03