Home ProductsCummins Diesel Generator Set

DC24V Electric Industrial 50kVA Cummins Diesel Generator Set with 3 Phase and 4 Wires

DC24V Electric Industrial 50kVA Cummins Diesel Generator Set with 3 Phase and 4 Wires

    • DC24V Electric Industrial 50kVA Cummins Diesel Generator Set with 3 Phase and 4 Wires
    • DC24V Electric Industrial 50kVA Cummins Diesel Generator Set with 3 Phase and 4 Wires
    • DC24V Electric Industrial 50kVA Cummins Diesel Generator Set with 3 Phase and 4 Wires
    • DC24V Electric Industrial 50kVA Cummins Diesel Generator Set with 3 Phase and 4 Wires
  • DC24V Electric Industrial 50kVA Cummins Diesel Generator Set with 3 Phase and 4 Wires

    Product Details:

    Place of Origin: Guangdong, China
    Brand Name: Laurel
    Certification: CE&ISO
    Model Number: LF50C5

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 set
    Price: Negotiable
    Packaging Details: Wood or plastic film package and depend on Client's requirement.
    Delivery Time: 5-15 days according to the quantity
    Payment Terms: 30% T / T in advance and 70% balance before shipment or 100% L / C at sight
    Supply Ability: 1000 sets per month
    Contact Now
    Detailed Product Description
    Prime Power: 40KW/50KVA Rated Voltage(V): 400/230
    Rated Frequency(HZ): 50 Rated Speed(RPM): 1500
    Power Factor: 0.8(lagging) Genset Weight(kg): 7700

    DC24V Electric Industrial 50kVA Cummins Diesel Generator with 3 Phase and 4 Wires

     

     

    Product Description:
    1.Engine, alternator, radiator, auto control panel.
    2.Base frame, base fuel tank, Flexible pipes, flange, exhaust silencer .
    3.Battery, battery charger, battery wires, internal cables, circuit breaker.
    4.Manual books of engine, alternator, genset, control panel, wires diagram.
    5.optional parts: Soundproof, ATS (automatic transfer switch), AMF panel, Trailer, Parallel system by your extra choose

    Specification of genset:

     

    Gensets model LF50C5
    Prime power 40KW/50KVA
    Rated Voltage(V) 400/230
    Rated frequency(HZ) 50
    Rated Speed(RPM) 1500
    Power Factor 0.8(lagging)
    Dimensions(mm) (L×W×H) 1700x730x1285 Open type
    Genset Weight(kg) 7700
    Dimensions(mm) (L×W×H) 2400x1000x1560 Silent type
    Genset Weight(kg) 1270

     

    Specification of diesel engine:

     

    Engine model 4BTA3.9-G2
    Output power 55kW/69kVA
    Number of Cylinders 4
    Cylinder arrangement In-line
    Cycle Four stroke
    Aspiration Turbo, Water / Air DC
    Bore×Stroke (mm×mm) 102 x 120
    Displacement (Liter) 3.9
    Compression Ratio 16.5:1
    Speed Governor Electronic
    Cooling System Forced Water Cooling Cycle
    Total lubrication system capacity (L) 16.4
    Fuel Consumption at 100% Load (g/kw.h) 220
    Starting Method DC24V electrical starting

     

    Specification of alternator:

     

    Alternator brand Stamford
    Alternator model UCI 224D
    Rated power 40kW
    Number of Phase 3
    Connecting Type 3 Phase and 4 Wires
    Number of Bearing 1
    Protection Grade IP23
    Altitude ≤1000m
    Exciter Type Brushless ,Self-exciting, AVR automatic voltage regulating,
    100% Copper winding wire
    Insulation Class H
    Telephone Influence Factor (TIF) ≤50
    THF ≤2%
    Voltage Regulation, Steady State ≤±1%
    Transient State Voltage ≤-15%~+20%

     


    RELIABLE AND SAFE
    * Load from 0-100%, frequency vibration within 0.25%
    * No load wire volts max undulation ratio within 0.5%
    * The fully covered load centre houses all the outlets, compression terminals, and circuit breakers
    * Fully PC or front panel configuration, automatic shutdown when fault condition occurs


    GOOD COOLING SYSTEM
    Exhaust silencing system totally enclosed for operator safety
    50 degree radiator as standard, oil cooler, drain tap


    CONTROL SYSTEM
    Laurel Generator controllers integrating digital, intelligent and network technigues are used as the automatic control systems for diesel generators. It can carry out functions including automatic start/stop, data measure and alarming

    Upon detection of a mains (utility) failure the module automatically starts the generating sets. Once the mains (utility) power has been
    restored it instructs the generator set to stop

    STANDARD CONTROL SYSTEM
    *Micro-processor cored digital system
    *Multipe languages, automatic control
    *Generator measurements:U1-U3,I1-I3,Hz,KW,KVAr,KWh,Cos.
    *Four operation modes:OFF-Manual starting-Automatic starting-Automatic test
    *Mains measurements:U1-U3,Hz
    *Analog Oil pressure,Water temperature,battery voltage,engine speed r.p.m,hours counter
    *Engine protections:low fuel level,low oil pressure,high engine temperature etc
    *3-phase Generator protections:over/under voltage,over/under frequency etc
    DC24V Electric Industrial 50kVA Cummins Diesel Generator Set with 3 Phase and 4 Wires

    DC24V Electric Industrial 50kVA Cummins Diesel Generator Set with 3 Phase and 4 Wires

    Contact Details
    Guangzhou Laurel & Honesty Holdings

    Contact Person: Mr.Roger

    Send your inquiry directly to us (0 / 3000)

    Contact

    Address: No.812-814, Nandidong road, Qiaonan street, Panyu district, Guangzhou city, Guangdong, China