Detail Information |
|||
Engine: | Googol QTA2160G1B Engine, Water Cooled | Alternator: | Italy Meccalte, Marathon, Engga, Etc |
---|---|---|---|
Controller: | Deepsea, Datakom, Comp, Etc | Application Area: | Industry Project, Hospital, Hotel, Etc |
Output Type: | AC Three Phase | Speed: | 1500RPM |
Frequency: | 50Hz | Rated Voltage: | 230V/400V Adjustable |
Rated Powerr: | 640kW 800kVA | ||
High Light: | Diesel Powered Generator,Diesel Power Generator Set |
Product Description
8 Cylinder Diesel Generator Set With 640kw 800kva Googol Engine
Performance Feature
Engine and alternator shall be mounted on a same frame steel skid.
Built-in damper for anti-vibration.
World most famous brand diesel engine.
World famous brand AC alternator.
Advanced and reliable control module
Full range protection function and alarm shutdown feature.
Specifications:
Generator Model |
LF882 |
Genset Prime Power |
640kW/800kVA |
Engine Model |
|
Googol QTA2160G1B |
Speed |
rpm |
1500 |
Frequency |
Hz |
50 |
Rating Output |
|
|
Standby Output (LTP) |
kW |
807 |
Prime Output (PRP) |
kW |
739 |
Engine Continuous Power (COP) |
kW |
705 |
Typical Prime Generation Output |
kVA |
800 |
Typical Prime Generation Output |
kW |
640 |
Typical Prime Generation Output |
kVA |
760 |
Basic Performance Datasheet |
|
|
Injection Type |
|
Direct Injection |
Configuration |
|
Vee |
No. of Cylinders |
|
8 |
Displacement |
l |
35.4 |
Bore |
mm |
170 |
Stroke |
mm |
195 |
Compression Ratio |
|
13.5:1 |
Piston Speed |
m/s |
9.75 |
Rotation Direction (from flywheel) |
|
Counter Clockwise |
Static Speed Droop |
|
≤ 5% |
Number of Flywheel Teeth |
|
218 |
Flywheel House Size |
|
SAE00-18 |
Fuel System |
|
|
Governor Type |
|
Electrical |
Engine Output at genset prime output |
kW |
703 |
Fuel Consumption at 25% of genset prime output |
l/h |
42.88 |
Fuel Consumption at 50% of genset prime output |
l/h |
83.67 |
Fuel Consumption at 75% of genset prime output |
l/h |
124.25 |
Fuel Consumption at 100% ofgenset prime output |
l/h |
165.67 |
Engine Dimension |
|
|
Length |
mm |
2596 |
Width |
mm |
1459 |
Height |
mm |
1820 |
Engine Dry Weight w/o Cooling System |
kg |
3500 |
Alternator Feature
Brush-less, 4 poles, rotation magnet.
IP21-23(NEMA1) enclosure is standard for all industrial alternators.
The insulation system is Class H
Simple installation and maintenance, with easy access to terminals, rotating diodes and coupling bolts.
Wide range of flange adaptors and single bearing disc coupling.
Standard 2/3 pitch windings avoid excessive neutral currents
AVR auto voltage regulator, auto exciter, auto adjustment
Standard Accessory
Common steel base frame, Damper, Exhaust silencer, Flexible pipe, Battery and connecting wires,
Operation manual and document.
Optional Accessory
Engine coolant and oil heater, Alternator space heater, Cooling for heat exchanger, Control system
with RS232/485 communication interface, Battery charger by main supply, Fuel-water separator,
Daily fuel tank, ATS & paralleling system, and Moving Trailer.
Silent Canopy Description
Standard Accessory:
Steel Weatherproof Canopy
Built In Fuel Tank For 8 Hours Running
Built In Control Panel
Built In Start Battery
Power Output Rapid Insert
Windows for Looking
Air Louver for Intake & Exhaust
Exhaust Gas Silencer
Soundproof Type
ATS SYSTEM
For emergency power usage in building, Auto transfer switch (ATS) is essential. ATS can
automatic transfer load from Mains power supplying to Emergency power. In normal, when
the Main power supplying failure or voltage drop below 80% of normal voltage, ATS will auto
start Emergency generator set after a preset time of 0-10 sec (adjustable according to the users).
Once generator reach at rated speed, the ATS will transfer the load to emergency generator sets
automatically.
Our main products:
We are engaged in the production and sale of diesel generator sets, generators, engines, water pumps and other agricultural machinery products. We have obtained the relevant certifications such as ISO, CE,ROHS, GS, TUV etc.
Guarantee Service
We have 34 years of export experience. We deliver not only our products, but also our value-added technical support and after-sales service. We ensure that all our original purchasers get Laurel & Honesty Holdings products guarantee under this warranty statement.
Warranty Period
We will provide a warranty period of 24 months or 1200 operating hours to the original purchasers for all our Diesel associated products, and a warranty period of 12 months or 1000 operating hours to the original purchasers for all gasoline associated products. The warranty period starts from the day of delivery to the original retail purchaser.
Enter Your Message