Handle Diesel Generator Balloon Project Light Tower with Direct Injection Diesel Engine
Contact Person : Roger Xie
Phone Number : +86 13533071813
WhatsApp : +8613533071813
Minimum Order Quantity : | 1 set | Price : | Negotiable |
---|---|---|---|
Packaging Details : | Standard packing as request | Delivery Time : | 7-15 days after receiving your deposit |
Payment Terms : | 30% T/T in advance and 70% balance before shipment/ 100% L/C at sight | Supply Ability : | 1000 sets per month |
Place of Origin: | Guangdong China | Brand Name: | Laurel |
---|---|---|---|
Certification: | CE | Model Number: | LF120GF |
Detail Information |
|||
Prime Power: | 120KW | Standby Power: | 132KW |
---|---|---|---|
Voltage: | 400 / 230V | Frequency: | 50HZ / 1500 Rpm |
Power Factor: | 0.8(lag) | Governor Type: | Electric |
High Light: | Diesel Gensets,Cummins Power Generator |
Product Description
150KVA Soundproof Cummins Diesel Generating Set Electric 6 Cylinders in Line Brushless
General feature
Coupled with Cummins diesel engine and Dingol alternator
24V DC start motor and storage battery
Brush-less, Self-excited, IP22, insulation class H alternator
40ºC radiator as standard
Smartgen HGM6110 Digital Auto Start
Silent type
All generator sets are gone through rigorous testing before being released to the market place, including 50% load, 75% load, 100% load , 110% load and all protection function (overspeed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
Genset Main Technical Data
Generator Model | LF120GF |
Prime power | 120KW |
Standby power | 132KW |
Voltage | 400 / 230V |
Frequency | 50HZ / 1500 rpm |
Power factor | 0.8(lag) |
Governor type | Electric |
Prime Power : Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97; A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.
Standby Power Rating : The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.
Voltage regulation
Voltage regulation maintained within ±0.5% as follow:
Power factor Between 0.8~1.0 lag
From no load to full load, any steady load
Speed droop variation under 4.5%
Frequency/Speed undulation
Change load from 0-100%, Frequency/Speed Droop Ratio within 5%
Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%
Effect factor of telecom
Telephone Influence Factor (TIF) : Less than 50
THF : Less than 2%
ISO8528, GB/T2820
EN12601:2001, EN60034-22:1997, EN60204-1:2006
ISO9001:2008 Quality Control System
Dimension and Weight
Open Type
Overall size (L*W*H)
2310*890*1570
Weight: 2200kg
For reference only
silent Type
Overall size (L*W*H)
2960*1210*1700
Weight: 2700kg
For reference only
ENGINE SPECIFICATION
Cummins Diesel Engine
Technical Data
Engine Model | LE6BTAA5.9-G12 |
Configuration | 4 cycle , 6 cylinders in line |
Aspiration | Turbocharged after air-air cooled |
Bore×Stroke | 102 x120 mm |
Rated speed | 1500rpm |
Displacement | 5.9 L |
Prime power | 140KW |
Speed Governor | Electrical |
Cooling System | Water-cooled , 40ºC Radiator As Standard |
Speed Stability (%) | ≤5% |
Fuel Consumption at 100% Load | 208g/kw.h |
Starter Motor | DC24V |
Alternator SPECIFICATION
Technical Data
Brand | Dingol |
Alternator Model | DG274EL |
Capacity | 120KW |
Voltage | 400 / 230V |
Frequency & Speed | 50HZ / 1500RPM |
Exciter type | Brush-less, Self-excited |
Power factor | 0.8 |
Voltage Adjust range | ≥5% |
Voltage Regulation NL-FL | ≤±0.5% |
Insulation Grade | H |
Protection Grade | IP22 |
Control System
Standard: Smartgen HGM6110 Digital Auto Start
Providing the standard functions as follows:
(Also can be made according to the customers' special requirements)
*Start/Stop controller
*Ampere meter
*Voltmeter and selector switch
*Frequency meter/ Water temperature gauge/ Oil pressure gauge/ Hour counter/ Battery voltage meter
*Emergency stop push-button
*Alarm System: Over speed,High Engine Temperature
Low Oil Pressure,Charge Fail
*Protection System:Over speed,High Engine Temperature,Low Oil Pressure,Emergency Stop. And the other protection function pre-setting
Accessories
Bellow,flange,industrial muffler,battery,battery connection line,certificate,operation instruction,one set data.
About 6-8 hours tank
The circuit breaker
Enter Your Message